HTabsOverviewPart number: 5.4103.20.x41 Herefrom, control- and warning signals can be derived. The precipitation is detected opto-electronically via a measuring area of approx. 25 cm².Output of the measuring signal as intensity-dependent analogue value.Integrated heating avoids snow covering or freezing of the instrument during winter operation.Delivery including mast holder, which can be used for wall mounting, as well. Precipitation Precipitation Sensor - 5.4103.20.x41.pdf SpecificationMeasurement Parameter: PrecipitationSpecification: Part number: 5.4103.20.x41 Precipitation Measuring range 0 ... 10 mm/min Collecting area 25 cm² Meas. principle optical, infrared photo sensor Particle size > 0.2 mm Data output analog Type 4.0 … 8.0 mA ( 0 ... 0.01 mm/min.)8.0 … 12.0 mA ( 0.01 ... 0.1 mm/min.)12.0 ... 16.0 mA ( 0.1 ... 1.0 mm/min.)16.0 ... 20.0 mA ( 1.0 ... 10 mm/min.) Output type Precipitation intensity Operating voltage Electronic 24 V AC/DC ±15% Current consumption ca. 90 mA Heating max. 1 A General Ambient temp. -30 ... +60 °C Protection IP 65 Dimension 130 x 140 x 40 mm Weight 0.4 kg Further InfoDocuments: Precipitation Precipitation Sensor - 5.4103.20.x41.pdf