HTabsOverviewPart number: 4.3820.34.398More than 35 different measurement values are available, for ex.:• Orthogonal wind velocityvectors (X- and Y-distance)• Scalar wind velocity• Wind direction• Acoustic-virtual temperature• Acoustic-virtual temperature of the orthogonal measurement distances (X- and Y-distance)• Standard deviation of the vectorial wind velocity(X and Y-distance)• Standard deviation of the scalar wind velocity• Standard deviationof the wind direction• Standard deviation of the acoustic-virtual temperature• Wind velocity of the gust acc. to WMO• Wind direction of the gust acc. to WMOThe instrument is especially suitable for the use in the fields of• Meteorology• Climatology• Regenerative energy, wind energy plant• Traffic engineering, aviation and navigation• Pollutant dispersal• Wind alarm devices, building construction and building safety• Indoor flow measurement• And in alpine field of applicationThe ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suitable for the measurement of gust- and peak values.The measurement values can be transmitted digitally and/or in analogue form.The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.If necessary, the sensor arms are automatically heated in case of critical ambient emperatures. The possibility of malfunction, caused by icing, is minimized.Model no. 4.3820.3x.xxx, thanks to the additionally installed ultrasonic converter heating, is suitable even for the more difficult use in locations where frequently icing is to be expected Ultrasonic Anemometer 2D - 4.3820.34.398.pdf Part number: 4.382x.4x.xxxMore than 35 different measurement values are available, for ex.:• Orthogonal wind velocityvectors (X- and Y-distance)• Scalar wind velocity• Wind direction• Acoustic-virtual temperature• Acoustic-virtual temperature of the orthogonal measurement distances (X- and Y-distance)• Standard deviation of the vectorial wind velocity(X and Y-distance)• Standard deviation of the scalar wind velocity• Standard deviationof the wind direction• Standard deviation of the acoustic-virtual temperature• Wind velocity of the gust acc. to WMO• Wind direction of the gust acc. to WMOThe instrument is especially suitable for the use in the fields of• Meteorology• Climatology• Regenerative energy, wind energy plant• Traffic engineering, aviation and navigation• Pollutant dispersal• Wind alarm devices, building construction and building safety• Indoor flow measurement• And in alpine field of applicationThe ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suitable for the measurement of gust- and peak values.The measurement values can be transmitted digitally and/or in analogue form.The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.If necessary, the sensor arms are automatically heated in case of critical ambient emperatures. The possibility of malfunction, caused by icing, is minimized.Model no. 4.3820.3x.xxx, thanks to the additionally installed ultrasonic converter heating, is suitable even for the more difficult use in locations where frequently icing is to be expected Ultrasonic Anemometer 2D - 4.382x.4x.xxx_.pdf SpecificationMeasurement Parameter: Wind Speed and DirectionSpecification: Part number: 4.3820.34.398 Data output digital Interface RS485 / RS422 Baudrate 1200 ... 921600 Baud Data values instant. values, average values, standard deviation Output range 1 per 10 msec up to1 per 60sec Status signals heating, Meas section error, Temperature of meas section Data output analog Wind speed 0 ... 20 mA4 ... 20 mA0 ... 10 V2 ... 10 V Stromausgang max. 400 ê Wind direction 0 ... 20 mA4 ... 20 mA0 ... 10 V2 ... 10 V Voltage output min. 4000 ê Resolution 16 bit Data input analog (alternative) Chanels 3 Resolution 16bit Operating voltage Electronic 8 ... 60V DC or12 ... 42 V AC / 2.5 W Heating 24 V AC/DC, typ 240 W General Bus operation up to 98 sensors Electr. connection 8 pol. connector Mounting on a mast tube 1,5`` Housing stainless steel (V4A) AiSi316Ti Protection IP 65 Dimension Ø 424 mm x 287 mm Weight 2.5 kg Part number: 4.382x.4x.xxx Wind speed Measuring range 0 ... 85 m/s Resolution 0.1 m/s (standard)0.01 m/s (user defined) Accuracy ±0.1 m/s rms ( < 5 m/s )±2 % rms ( 5 ... 85 m/s ) Wind direction Measuring range 0 ... 360 ° Resolution 1 °1 ° (standard)< 1 ° (user defined) Accuracy ±1 ° @ WS 1 ... 60 m/s±2 ° @ WS 60 ... 85 m/s Virtual temp. Measuring range -50 ... +80 °C Resolution 0.1 K Accuracy ±0.5 K @ WS < 35 m/s Data output digital Interface RS485 / RS422 Baudrate 1200 ... 921600 Baud Data values instant. values, average values, standard deviation Output range 1 per 10 msec up to1 per 60 sec Status signals heating, Meas section error, Temperature of meas section Data output analog Wind speed 0 ... 20 mA4 ... 20 mA0 ... 10 V2 ... 10 V Stromausgang max. 400 ê Wind direction 0 ... 20 mA4 ... 20 mA0 ... 10 V2 ... 10 V Voltage output min. 4000 ê Resolution 16 bit Data input analog (alternative) Chanels 3 Resolution 16bit Operating voltage Electronic 8 ... 78 V DC or12 ... 55 V AC / 2.5 W Heating 48 V AC/DC, typ 280 W General Bus operation up to 98 sensors Electr. connection 8 pol. connector Mounting on a mast tube 1,5`` Housing stainless steel (V4A) AiSi316Ti Protection IP 67 Dimension Ø 424 mm x 287 mm Weight 2.5 kg Further InfoDocuments: Ultrasonic Anemometer 2D - 4.3820.34.398.pdf Ultrasonic Anemometer 2D - 4.382x.4x.xxx_.pdf