HTabsOverview Part number: 4.3151.00.020Special characters are a defined and optimised, dynamic behaviour as well as:• High level of measuring accuracy and resolution• High damping ratio at a small delay distance• Low starting threshold• Very low power consumption• No wear of the potentiometer due to mechanical stress• Overvoltage and reverse polarity protectionThe measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems. For winter operation the instrument (4.3151.00.x2x) is equipped with an electronically regulated heating. Wind Direction Transmitter First Class - 4.3151.00.020.pdf Part number: 4.3151.00.400Special characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as digital signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.Characteristic:The WD transmitter can acquire the WS signals of 4.3352.x.000, and add the parameter wind speed to its serial data telegram Wind Direction Transmitter First Class - 4.3151.00.400.pdf Part number: 4.3151.10.400Special characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as digital signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.Characteristic:The WD transmitter can acquire the WS signals of 4.3352.x.000, and add the parameter wind speed to its serial data telegram Wind Direction Transmitter First Class - 4.3151.10.400.pdf Part number: 4.3151.00.401Special characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as digital signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.Characteristic:The WD transmitter can acquire the WS signals of 4.335x.x.000, and add the parameter wind speed to its serial data telegram Wind Direction Transmitter First Class - 4.3151.00.401.pdf Part number: 4.3151.10.401Special characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as digital signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.Characteristic:The WD transmitter can acquire the WS signals of 4.335x.x.000, and add the parameter wind speed to its serial data telegram Wind Direction Transmitter First Class - 4.3151.10.401.pdf Part number: 4.3151.x0.3xxSpecial characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems. For winter operation the instrument (4.3151.10.xxx) is equipped with an electronically regulated heating. Wind Direction Transmitter First Class - 4.3151.x0.3xx.pdf Part number: 4.3151.00.xxxSpecial characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems. For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating. Wind Direction Transmitter First Class - 4.3151.00.xxx_.pdf Part number: 4.3151.10.xxxSpecial characters are a defined and optimised, dynamic behaviour as well as:• High measurement accuracy and resolution• High damping with small distance constant• Low starting value• Low power consumption• Simple mountingThe measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems. For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating. Wind Direction Transmitter First Class - 4.3151.10.xxx_.pdf SpecificationMeasurement Parameter: Wind DirectionSpecification: Part number: 4.3151.00.020 Wind direction Measuring range 0 ... 360 ° Resolution 0,35 ° Accuracy ± 1 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Operating voltage Potent. / Electronik 3,3 ... 12 VDC Current consumption 0,4 mA @ 3,3V0,5 mA @ 5V0,8 mA @ 10V0,9 mA @ 12V Heating 24 V AC/DC, 25 W General Ambient temp. -50 °C ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Material aluminium anodised, stainless steel Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.00.400 Wind direction Measuring range 0 ° ... 360 ° Resolution 0.1 ° Accuracy ±1 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Data output digital Interface RS485 Baudrate 1200 ... 57600 Baud Protocol ASCII Operating voltage Electronic 3.3 ... 42V DC Current consumption 0.5 mA without data query1.0 mA with data query Heating 24 V AC/DC, 25 W General Ambient temp. -50 ... +80 °C, all occurring situations of rel. humidity Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1 `` Material aluminium anodised, stainless steel Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.10.400 Wind direction Measuring range 0 ° ... 360 ° Resolution 0.1 ° Accuracy ±1 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Data output digital Interface RS485 Baudrate 1200 ... 57600 Baud Protocol ASCII Operating voltage Electronic 3.3 ... 42V DC Current consumption 0.5 mA without data query1.0 mA with data query Heating without heating General Ambient temp. -50 ... +80 °C, all occurring situations of rel. humidity Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1 `` Material aluminium anodised, stainless steel Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.00.401 Wind direction Measuring range 0 ° ... 360 ° Resolution 0.1 ° Accuracy ±1 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Data output digital Interface RS485 Baudrate 1200 ... 57600 Baud Protocol Modbus RTU Operating voltage Electronic 3.3 ... 42V DC Current consumption 0.5 mA without data query1.0 mA with data query Heating 24 V AC/DC, 25 W General Ambient temp. -50 ... +80 °C, all occurring situations of rel. humidity Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1 `` Material aluminium anodised, stainless steel Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.10.401 Wind direction Measuring range 0 ° ... 360 ° Resolution 0.1 ° Accuracy ±1 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Data output digital Interface RS485 Baudrate 1200 ... 57600 Baud Protocol Modbus RTU Operating voltage Electronic 3.3 ... 42V DC Current consumption 0.5 mA without data query1.0 mA with data query Heating without heating General Ambient temp. -50 ... +80 °C, all occurring situations of rel. humidity Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1 `` Material aluminium anodised, stainless steel Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.x0.3xx Wind direction Measuring range 0 ... 360 ° Accuracy ± 1.5 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.5 macc. to ASTMD 5096-96 Damping ration > 0.28acc. to ASTMD 5096-96 Operating voltage Potent. / Electronik > 0 ... 30 V DC Current consumption = Us / 2 kê Heating 24 V AC/DC, 25 W General Ambient temp. -50 °C ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Material aluminium, anodised Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.00.xxx Wind direction Measuring range 0 ... 360 ° Resolution 0.35 ° Accuracy 1 ° Starting value < 0.5 m/s at 10 °acc. to ASTM D 5096-96< 0.2 m/s at 90 °acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Operating voltage Electronic 3.3 ... 42 V DC Heating 24 V AC/DC, 25 W General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Material aluminium, anodised Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Part number: 4.3151.10.xxx Wind direction Measuring range 0 ... 360 ° Resolution 0.35 ° Accuracy 1 ° Starting value < 0.5 m/s at 10°acc. to ASTM D 5096-96< 0.2 m/s at 90°acc. to VDI3786 page 2 Distance constant < 1.8 macc. to ASTMD 5096-96 Damping ration > 0.3acc. to ASTMD 5096-96 Operating voltage Electronic 3.3 ... 42 V DC Current consumption 1.4 mA standby General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Material aluminium, anodised Protection IP 55 Dimension Ø 450 x 410 mm Weight 0.7 kg Mounting Ø 35 x 25 mm Further InfoDocuments: Wind Direction Transmitter First Class - 4.3151.00.020.pdf Wind Direction Transmitter First Class - 4.3151.00.400.pdf Wind Direction Transmitter First Class - 4.3151.10.400.pdf Wind Direction Transmitter First Class - 4.3151.00.401.pdf Wind Direction Transmitter First Class - 4.3151.10.401.pdf Wind Direction Transmitter First Class - 4.3151.x0.3xx.pdf Wind Direction Transmitter First Class - 4.3151.00.xxx_.pdf Wind Direction Transmitter First Class - 4.3151.10.xxx_.pdf