HTabsOverviewPart number: 4.3351.00.000The wind transmitter is designed for the acquisition of the horizontal component of the wind velocity in the field of meteorology and environ- mental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400-12-1 for an Instrument of the accuracy class 0.5.Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value.The measuring value is available at the output as digital signal. It can be transmittedto display instruments, recording instruments, data loggers as well as to process control systems.For winter operation the instrument (4.3351.00.000) is equipped with an electronically regulated heating, which guarantees a smooth running of the ball bearings, and prevents the shaft and slot from icing-up. Wind Transmitter First Class Advanced - 4.3351.00.000.pdf Part number: 4.3351.00.xxxSpecial characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value. The measuring value is available at the output as analogue signal and as rectangular digital signal.For winter operation the instrument (4 .3351 .00 .xxx) is equipped with an electronically regulated heating. Wind Transmitter First Class Advanced - 4.3351.00.xxx_.pdf Part number: 4.3351.10.xxxSpecial characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value. The measuring value is available at the output as analogue signal and as rectangular digital signal.For winter operation the instrument (4 .3351 .00 .xxx) is equipped with an electronically regulated heating. Wind Transmitter First Class Advanced - 4.3351.10.xxx_.pdf Part number: 4.3352.00.000The wind transmitter is designed for the acquisition of the horizontal component of the wind velocity in the field of meteorology and environ- mental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400-12-1 Edition 2.0 for an Instrument of the accuracy class 0.9.Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value.The measuring value is available at the output as digital signal. It can be transmittedto display instruments, recording instruments, data loggers as well as to process control systems.For winter operation the instrument (4.3352.00.000) is equipped with an electronically regulated heating, which guarantees a smooth running of the ball bearings, and prevents the shaft and slot from icing-up. Wind Transmitter First Class Advanced - 4.3352.00.000.pdf Part number: 4.3351.10.000The wind transmitter is designed for the acquisition of the horizontal component of the wind velocity in the field of meteorology and environ- mental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400-12-1 for an Instrument of the accuracy class 0.5.Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value.The measuring value is available at the output as digital signal. It can be transmittedto display instruments, recording instruments, data loggers as well as to process control systems. Wind Transmitter First Class Advanced - 4.3352.00.000.pdf Part number: 4.3352.10.000The wind transmitter is designed for the acquisition of the horizontal component of the wind velocity in the field of meteorology and environ- mental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400-12-1 Edition 2.0 for an Instrument of the accuracy class 0.9.Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value.The measuring value is available at the output as digital signal. It can be transmittedto display instruments, recording instruments, data loggers as well as to process control systems. Wind Transmitter First Class Advanced - 4.3352.10.000.pdf SpecificationMeasurement Parameter: Wind SpeedSpecification: Part number: 4.3351.00.xxx Wind speed Measuring range 0 ... 75 m/s Accuracy < 1 % of meas. value ( 0.3 ... 50 m/s )or < ±0.2 m/s Linearity r > 0.99999 ( 4 ... 20 m/s ) Delay distance < 3 m ( aac. to ASTM D 5096-96 ) Data output digital Frequency 1082 Hz at 50 m/s Operating voltage Electronic 15 ... 24 V DC Heating 24 V AC/DC, max 25 W General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Protection IP 55 Survival speed 80 m/s ( min. 30 minutes ) Weight 0.5 kg Mounting Ø 35 x 25 mm Matirial housing aluminium, anodised Material cup star carbon-fiber glass reinforced Part number: 4.3351.00.000 Wind speed Measuring range 0 ... 75 m/s Accuracy < 1 % of meas. value (0.3 ... 50 m/s)or < ±0.2 m/s Linearity r > 0.99999 ( 4 ... 20 m/s ) Delay distance < 3 m ( aac. to ASTM D 5096-96 ) Data output digital Frequency 1082 Hz at 50 m/s Operating voltage Electronic 3.3 ... 48 V DC130 µA from 3,3 ... 15 V180 µA > 15 V Heating 24 V AC/DC, max 25 W General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Protection IP 55 Survival speed 80 m/s ( min. 30 minutes ) Weight 0.5 kg Mounting Ø 35 x 25 mm Matirial housing aluminium, anodised Material cup star carbon-fiber glass reinforced Part number: 4.3351.10.xxx Wind speed Measuring range 0 ... 75 m/s Accuracy < 1 % of meas. value ( 0.3 ... 50 m/s )or < ±0.2 m/s Linearity r > 0.99999 ( 4 ... 20 m/s ) Delay distance < 3 m ( aac. to ASTM D 5096-96 ) Data output digital Frequency 1082 Hz at 50 m/s Operating voltage Electronic 3.3 ... 48 V DC130 µA from 3,3 ... 15 V180 µA > 15 V General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Protection IP 55 Survival speed 80 m/s ( min. 30 minutes ) Weight 0.5 kg Mounting Ø 35 x 25 mm Matirial housing aluminium, anodised Material cup star carbon-fiber glass reinforced Part number: 4.3352.00.000 Wind speed Measuring range 0 ... 75 m/s Accuracy < 1 % of meas. value (0.3 ... 50 m/s)or < ±0.2 m/s Linearity r > 0.99999 ( 4 ... 20 m/s ) Inclined flow < 0.1% ( mean deviation from cosinus line at12 m/s ; ±20 ° ) Delay distance < 3 m ( aac. to ASTM D 5096-96 ) Data output digital Frequency 1082 Hz @ 50 m/s Operating voltage Electronic 3.3 ... 48 V DC130 µA from 3,3 ... 15 V180 µA > 15 V ... 48 V Heating 24 V AC/DC, max 25 W General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Protection IP 55 Survival speed 80 m/s ( min. 30 minutes ) Weight 0.5 kg Mounting Ø 35 x 25 mm Matirial housing aluminium, anodised Material cup star carbon-fiber glass reinforced Part number: 4.3351.10.000 Wind speed Measuring range 0 ... 75 m/s Accuracy < 1 % of meas. value (0.3 ... 50 m/s)or < ±0.2 m/s Linearity r > 0.99999 ( 4 ... 20 m/s ) Delay distance < 3 m ( aac. to ASTM D 5096-96 ) Data output digital Frequency 1082 Hz at 50 m/s Operating voltage Electronic 3.3 ... 48 V DC130 µA from 3,3 ... 15 V180 µA > 15 V Heating without heating General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Protection IP 55 Survival speed 80 m/s ( min. 30 minutes ) Weight 0.5 kg Mounting Ø 35 x 25 mm Matirial housing aluminium, anodised Material cup star carbon-fiber glass reinforced Part number: 4.3352.10.000 Wind speed Measuring range 0 ... 75 m/s Accuracy < 1 % of meas. value (0.3 ... 50 m/s)or < ±0.2 m/s Linearity r > 0.99999 ( 4 ... 20 m/s ) Inclined flow < 0.1% ( mean deviation from cosinus line at12 m/s ; ±20 ° ) Delay distance < 3 m ( aac. to ASTM D 5096-96 ) Data output digital Frequency 1082 Hz @ 50 m/s Operating voltage Electronic 3.3 ... 48 V DC130 µA from 3,3 ... 15 V180 µA > 15 V ... 48 V Heating without Heating General Ambient temp. -50 ... +80 °C Electr. connection 8 pol. plug connection Mounting onto mast tube Ø 1`` Protection IP 55 Survival speed 80 m/s ( min. 30 minutes ) Weight 0.5 kg Mounting Ø 35 x 25 mm Matirial housing aluminium, anodised Material cup star carbon-fiber glass reinforced Further InfoDocuments: Wind Transmitter First Class Advanced - 4.3351.00.xxx_.pdf Wind Transmitter First Class Advanced - 4.3351.00.000.pdf Wind Transmitter First Class Advanced - 4.3351.10.xxx_.pdf Wind Transmitter First Class Advanced - 4.3352.00.000.pdf Wind Transmitter First Class Advanced - 4.3352.10.000.pdf